VAE-430 Demo DEMO
No output
VAE-430 Relay Protection Test Software
Demo build · no hardware connection
COM3 · Connected VAE-430 50 Hz
VAE-430 · PC Control Software

Relay protection
testing, organized.

Launch any of the 20 test modules from one place. The instrument stays connected on COM3 while you set up, run and review tests.

Open 3-Phase AC Test → View test records

3-Phase AC Test

Three voltages, three currents, phase angle and power.

Open →

DC Test

DC voltage and current output with contact monitoring.

Open →

AC/DC Test

Superimposed AC and DC quantities with digital inputs.

Open →

Harmonic Test

Individual harmonic amplitudes and percentage content.

Open →

State Sequence 1

Build multi-state sequences with hold and transition times.

Open →

More modules

Line, element, differential, automation and comprehensive tests.

Browse all 20 →
Recent DEMO-220kV Line 1 · 3-Phase AC Test Pass Today 14:32 · 00:32.5
Ready · COM3 · 19200 8N1
SettingsOpen Module
VAE-430 Relay Protection Test Software
3-Phase AC Test · Manual output
Device · not connected VAE-430 50 Hz

Output Settings

Balanced
UaV°f
UbV°f
UcV°f
IaA°f
IbA°f
IcA°f

Phasor & Waveform

PhasorWaveformPower
U avg · set
57.74 V
I avg · set
1.000 A
Frequency
50.00 Hz
Power · calc
173.2 W
Phasor · U max 57.74 V · I max 1.000 A · f 50.00 Hz
Device idle · not connected
ConnectStopStart Test
VAE-430 Relay Protection Test Software
Distance & Zero Sequence · Distance Protection
Device · not connected VAE-430 50 Hz

R-X Plane

MhoQuad
R-X PlaneRecords
Z measured
4.00 Ω
Angle
78.0 °
Test current
1.00 × In
Fault
A-N Ground
Distance zone · simulated
No.FaultZ (Ω)AngleTimeResult
Simulation idle · frontend prototype · no device telemetry
ConnectStopStart Test
VAE-430 Relay Protection Test Software
Harmonic & DC · Current Harmonic Test
Simulated · no COM VAE-430 50 Hz

Harmonic Analysis

WaveformSpectrumRecords
I true RMS
1.021 A
THD
20.8 %
Crest factor
1.45 ×
Fundamental
1.000 A
Waveform · 2 cycles · simulated
No.StepI RMSTHDMeasuredResponse
Simulation idle · frontend prototype · no device telemetry
Save setupStopStart Test
VAE-430 Relay Protection Test Software
State Sequence 1 · State Series I
Device · not connected 0005 device control 50 Hz · fixed

State Parameters

State 01
Any 0–120 V
State ReversingTime + DI may coexist · Key/GPS are exclusive
Time DI Key GPS
DI trigger
OR AND
DO in state DO1 close DO2 close DO3/DO4 n/a
The 0005 table carries only Ux / Ua / Ub / Uc / Ia / Ib / Ic amplitude + angle. Triggers, times, DI mask and DO are PC-side sequencing fields. Per-state frequency is intentionally absent: the original 0005 protocol has no frequency field. 3U0 / √3×3U0 Ux modes are deferred until short-circuit calculation is implemented.
Device idle · not connected
Connect Stop Start Test
VAE-430 Relay Protection Test Software
Binary I/O & Timing · Contact monitor
Events · from device VAE-430 DI1–DI7

Digital Inputs

LiveEvents
Timing result
—
Arm a pair, then trigger the contacts.
Last event
—
No contact activity since the session started.
Waiting for the device. DI events arrive unsolicited; the screen derives contact state from the edges it receives.
Idle · no contact activity
LiveEvent log
VAE-430 Relay Protection Test Software
I-t Characteristic · Inverse-time overcurrent
Simulation · no device VAE-430 IEC SI

I–t Characteristic

CurveTable
log–log · I/Is 0.5–20 · t 0.01–100 s
Time at injected current
—
Computed from the selected characteristic.
Pickup verdict
—
Run a test to populate.
Waiting for a run. Curve sampling uses the selected characteristic; the marker shows the injected current.
Idle · simulation
CurveTable
VAE-430 Relay Protection Test Software
Frequency & df/dt · under/over frequency element
Simulation · no device VAE-430 81O · step

Frequency vs Time

ChartTable
f–t · setpoint and trip points
Measured pickup
—
Run a test to populate.
Δf vs setpoint
—
Signed error, measured − setpoint.
Trip time
—
From the step edge to the trip.
Waiting for a run. In ramp mode every selected rate is swept and the pickup is read at the trip instant.
Idle · simulation
ChartTable
VAE-430 Relay Protection Test Software
Impedance Characteristic · zone boundary search
Simulation · no device VAE-430 0204 · mho

R–X Plane

ChartTable
R–X · declared characteristic and searched boundary
Worst ΔZ
—
Run a search to populate.
Worst Δ
—
Tolerance applies to this figure.
Boundary points
—
Lines outside the zone report none.
Waiting for a search. Each line is bracketed between a known operate and a known non-operate point, then halved until the step is finer than the resolution.
Idle · simulation
ChartTable
VAE-430 Relay Protection Test Software
Differential Protection · ratio-restraint characteristic
Simulation · no device VAE-430 0301 · 6I

Ibias – Idiff Plane

ChartTable
Ibias–Idiff · declared restraint characteristic and searched boundary
Worst Δ
—
Tolerance applies to this figure.
Boundary points
—
Lines that cannot cross report none.
Restraint
—
2nd harmonic blocking.
Waiting for a search. Each bias line is bracketed between a known non-operate and a known operate point, then halved until the step is finer than the resolution.
Idle · simulation
ChartTable
VAE-430 Relay Protection Test Software
Differential Relay · operate time and return ratio
Simulation · no device VAE-430 0302 · single relay

Operate Time

ChartTable
Operate time vs multiple of the boundary
Worst t
—
Judged points only.
Timing points
—
Points below 2x are reference only.
Return coeff.
—
Return test runs with every search.
Waiting for a test. Each point is a fixed multiple of the operate boundary at the set bias.
Idle · simulation
ChartTable
VAE-430 Relay Protection Test Software
Differential Harmonic · second-harmonic blocking threshold
Simulation · no device VAE-430 0303 · auto

Blocking Threshold

ChartTable
2nd-harmonic blocking threshold
Threshold h
—
Auto mode measures it.
Δ vs setting
—
Measured minus setting.
State
—
Manual mode tests one ratio.
Waiting for a test.
Idle · simulation
ChartTable
VAE-430 Relay Protection Test Software
Fault Recurrence · COMTRADE import and waveform replay
Simulation · no device VAE-430 0502 · replay

Record Waveform

ChartTable
No record loaded
Cursor
—
Hover the waveform.
Fidelity
—
16-bit D/A assumption.
Transfer
—
Nothing is sent.
Each lane is scaled to its own range — amplitudes are not comparable across lanes.
Idle · simulation
ChartTable
VAE-430 Relay Protection Test Software
Group Test 1 · line protection whole-scheme fault sequence
Simulation · no device VAE-430 0201 · 0.95×Z

Fault Scheme

R-XPhasorSequence
Load only — no fault applied
Trip A
—
Phase A trip time.
Trip B
—
Phase B trip time.
Trip C
—
Phase C trip time.
Reclose
—
From fault inception.
Per. trip
—
Second trip after reclose.
Healthy phases are held at rated; the source impedance is not modelled.
Idle · simulation
R-XPhasorSequence
VAE-430 Relay Protection Test Software
Group Test 2 · trip matrix, breaker response, anti-pump and pole disagreement
Simulation · no device VAE-430 0202 · single-pole

Breaker Response

TimelineMatrixCheck
No trip — the fault is outside the zone
Trip output
—
From the matrix.
Pulse / travel
—
ms.
Closings
—
With / without anti-pump.
Disagreement
—
Longest window / setting.
Final A B C
—
C = closed, O = open.
The breaker is a state machine driven by the relay trip output.
Idle · simulation
TimelineMatrixCheck
VAE-430 Relay Protection Test Software
Backup Power Auto-switch · standby transfer, lockout inputs, breaker timing
Simulation · no device VAE-430 0401 · mutual

Transfer Response

TimelineSequenceConditions
Computed transfer response, not a measurement
Transfer time
—
Dead bus to restored.
Operations
—
Breaker operations issued.
Bus U at admit
—
Working bus voltage.
Source I at admit
—
Working source current.
Admitted at
—
Dead to admitted.
Computed response, not a measurement.
Idle · simulation
TimelineSequenceConditions
VAE-430 Relay Protection Test Software
Synchronism · sync window, slip, lead angle, breaker close time
Simulation · no device VAE-430 0402 · sync check

Synchronization Indicator

TimelineTableWindow
Computed angle sweep, not a measurement
Sync pulse
—
Inside the angle window.
Lead angle
—
Before the crossing.
Δφ at close
—
Residual at close.
Slip
—
|f1 − f2|.
Modulation rate
—
Step over pulse width.
Computed response, not a measurement.
Idle · simulation
TimelineTableWindow
VAE-430 Relay Protection Test Software
6-35 kV Line Protection · overcurrent, directional, frequency block, reclose
Simulation · no device VAE-430 0501 · line

Protection Element

TimelineVectorgraphRecords
Computed response, not a measurement
Action time
—
Computed trip instant.
Setting time
—
Definite delay.
Error
—
Actual − setting.
M = I / Iset
—
Operating quantity.
Angle / f ramp
—
Δφ to the setting.
Computed response, not a measurement.
Idle · simulation
TimelineVectorgraphRecords
VAE-430 Relay Protection Test Software
Power Direction & Impedance · sensitive angle, action current, action impedance, boundary search
Simulation · no device VAE-430 0103 · ang

Protection Action Boundary

SweepPlaneRecords
Computed boundary search, not a measurement
Boundary 1
—
First state change.
Boundary 2
—
Second state change.
Measured
—
From the sweep.
Setting
—
Nameplate value.
Error
—
Measured − setting.
Computed response, not a measurement.
Idle · simulation
SweepPlaneRecords
VAE-430 Relay Protection Test Software
DC Test · contact action and return on a stepped DC quantity
Simulation · no device VAE-430 0002 · volt

Step Response

RampRecords
Computed response, not a measurement
Action value
—
First step that closes the contact.
Return value
—
First step that opens it again.
Return coeff.
—
Return / action, as measured.
Action time
—
DUT time plus de-jitter.
Return time
—
DUT time plus de-jitter.
Computed response, not a measurement.
Idle · simulation
RampRecords
VAE-430 Relay Protection Test Software
AC/DC Test · DC offset plus a sine, read through the relay's own detector
Simulation · no device VAE-430 0003 · rms

Composite Output

WaveformRampRecords
Computed response, not a measurement
Action amplitude
—
AC level at the action point.
Detected
—
What the relay saw there.
Return amplitude
—
Where the contact opens.
Return coeff.
—
Return / action, as measured.
Action time
—
DUT time plus de-jitter.
Computed response, not a measurement.
Idle · simulation
WaveformRampRecords